BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Penn Engineering Events - ECPv6.15.18//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Penn Engineering Events
X-ORIGINAL-URL:https://seasevents.nmsdev7.com
X-WR-CALDESC:Events for Penn Engineering Events
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/New_York
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20230312T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20231105T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20240310T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20241103T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20250309T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20251102T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20240416T090000
DTEND;TZID=America/New_York:20240416T110000
DTSTAMP:20260403T154317
CREATED:20240410T212450Z
LAST-MODIFIED:20240410T212450Z
UID:11314-1713258000-1713265200@seasevents.nmsdev7.com
SUMMARY:ESE PhD Thesis Defense: "Multiferroic Micro Electromechanical Systems for Magnetic Sensing and Wireless Power Transfer in Biomedical Applications"
DESCRIPTION:Multiferroic micro-electromechanical systems (MEMS) enable small\, room temperature\, low power magnetic sensing and wireless power transfer (WPT) in biomedical applications. Current biomagnetic sensing relies on sensitive magnetometers like superconducting quantum interference devices (SQUIDs)\, but their reliance on cryogenic temperatures is undesirable. \n  \nThis thesis presents the theory\, design\, microfabrication\, and characterization of multiferroic MEMS magnetic sensors and WPT devices. Iron cobalt/silver (Fe50Co50/Ag) magnetostrictive material is coupled to piezoelectric aluminum nitride (AlN) to form a multiferroic sensor. Low frequency biomagnetic signals are upconverted around the length-extensional beam’s 7-16 MHz mechanical resonance to provide Q enhancement to the sensitivity. The up conversion exploits a nonlinear phenomenon of magnetostrictive materials with applied mechanical strain. For two devices studied\, modulated sensitivities of 58.4 mA/T and 37.7 mA/T were observed along with resolutions of 5.03 nT/√Hz and 2.72 nT/√Hz over a bandwidth larger than the biomagnetic frequency spectrum (0.1Hz to 1kHz). The sensors’ sensitivity was limited by Duffing nonlinearity and the relatively low piezoelectric coefficients of AlN. \n  \nTo improve sensitivity\, magnetoelectric sensors were fabricated using (Fe0.5Co0.5)0.92Hf0.08 coupled to 28% aluminum scandium nitride (Al0.72Sc0.28N). Increasing sensitivity improved the resolution from 5.03 nT/√Hz to 2.16 nT/√Hz. To delay the onset of thermal Duffing nonlinearity\, various anchoring tether lengths were explored in Fe0.5Co0.5/Ag – AlN magnetoelectric sensors to provide better heat conduction away from the structure. Also\, silicon dioxide (SiO2) was added to compensate the temperature coefficient of frequency (TCF). Larger achievable strain was verified before the onset of Duffing nonlinearity\, providing increased modulation of the Fe0.5Co0.5/Ag and a resolution of 1.11 nT/√Hz\, an 86% improvement when compared to a long tether device with the same layer stack (8.02 nT/√Hz) and a 78% improvement over the initial (Fe50Co50/Ag) – AlN long tether devices with no SiO2 thermal compensation. \n  \nWPT measurements were taken using (Fe50Co50/Ag) – AlN magnetoelectric devices. By sending a magnetic field at the device resonance frequency\, optimal WPT can be achieved. Devices were packaged with a magnetic bias circuit and the output power was measured. For a device at 7.44MHz\, an output power of 126.8 nW and a power density of 1196.2 uW/mm3 is projected when measuring with both electrodes.
URL:https://seasevents.nmsdev7.com/event/ese-phd-thesis-defense-multiferroic-micro-electromechanical-systems-for-magnetic-sensing-and-wireless-power-transfer-in-biomedical-applications/
LOCATION:Fisher Bennett Hall\, Room 401\, 3340 Walnut Street\, Philadelphia\, PA\, 19104\, United States
CATEGORIES:Dissertation or Thesis Defense
ORGANIZER;CN="Electrical and Systems Engineering":MAILTO:eseevents@seas.upenn.edu
END:VEVENT
END:VCALENDAR